update calculation for oil tank
This commit is contained in:
parent
9141c8d54e
commit
5fccc50c1e
@ -45,11 +45,11 @@ namespace OilTank {
|
||||
.addSecondary(
|
||||
Builder<Sensor>::instance(new Sensor{ "Level", id })
|
||||
.withUnitMseasure("%")
|
||||
.withValueTemplate("{{ 100 - ((value_json.sensor.value-7)|float*100/110)|round(2) }}")
|
||||
.withValueTemplate("{{ 100 - ((value_json.sensor.value-12)|float*100/120)|round(2) }}")
|
||||
.build()
|
||||
)
|
||||
.addDiagnostic(new VoltageSensor{id, "Battery voltage", "{{ value_json.sensor.diagnostic.voltage }}"})
|
||||
.addDiagnostic(new BatterySensor{id, "Battery level", "{{ ((states('sensor.oil_tank_battery_voltage')|float-3.6)|round(2)*100/1.6)|int }}"})
|
||||
.addDiagnostic(new BatterySensor{id, "Battery level", "{{ ((states('sensor.oil_tank_battery_voltage')|float-4.8)|round(2)*100/1.6)|int }}"})
|
||||
.build();
|
||||
}
|
||||
}
|
||||
|
||||
Loading…
x
Reference in New Issue
Block a user